960 constructions across 13 families. Each family page carries the full specification table for that family — conductor stranding, insulation, shielding, jacket, finished outer diameter, rated temperature and minimum bend radius. Every build below has been manufactured. Customer identities are not published: the data is shown, the buyer is not.
Match the duty cycle, not the cable name. Finished OD and temperature are the values these builds actually carry.
| Family | Builds | Finished OD | Typical temperature | Most used jacket |
|---|---|---|---|---|
| Tether and UAV Cable | 156 | 0.3 – 13.6 mm | -60 to +200 °C | High tensile aviation fiber |
| Subsea and Watertight Cable | 259 | 0.9 – 36.0 mm | -40 to +105 °C | TPU |
| Neutral Buoyancy Cable | 120 | 0.9 – 34.5 mm | -40 to +105 °C | TPU foam |
| Drag Chain Cable | 29 | 4.0 – 15.0 mm | -30 to +105 °C | PUR |
| Reeling and Hoist Cable | 33 | 6.5 – 62.0 mm | -40 to +90 °C | NBR |
| Flat and Elevator Cable | 33 | 4.8 – 128.5 mm | -20 to +80 °C | PVC |
| Spring and Spiral Cable | 17 | 0.7 – 13.0 mm | -30 to +105 °C | PUR |
| Silicone and High Temperature Cable | 34 | 0.5 – 13.8 mm | -60 to +200 °C | FEP |
| Robot and Conduit Inspection Cable | 38 | 3.8 – 19.1 mm | -40 to +105 °C | TPU |
| Data, Coax and Network Cable | 42 | 0.3 – 13.7 mm | -30 to +105 °C | PVC |
| LSZH Cable | 10 | 4.5 – 18.0 mm | -40 to +120 °C | LSZH |
| Solar Cable | 3 | — | -25 to +90 °C | — |
| Fixed Installation and General Purpose Cable | 186 | 0.2 – 58.0 mm | -30 to +105 °C | PVC |
A tether carries three things at once: power up, data down, and the mechanical load of the aircraft. Every con…
Seawater attacks a cable at three points: the conductor, the shield, and the jacket. These constructions answe…
On an inspection-class ROV the cable is a significant part of the vehicle's apparent weight. A standard subsea…
Cable inside a cable carrier sees constant back-and-forth travel at speed, for millions of cycles. Conductor s…
Winding puts two loads on a cable that a linear application never sees: tension along the axis, and torsion as…
A flat cable solves two geometric problems at once: it bends in one plane only, so it fits where a round cable…
A coiled cable keeps a run retracted without a take-up reel or a festoon. The construction trade-off is that t…
Above roughly 105 °C the standard compounds are out and the choice becomes silicone, PTFE or FEP. Each behaves…
A robot dress pack and a conduit inspection cable share a problem: the cable has to survive repeated tight-rad…
Signal cable is specified by impedance and attenuation rather than by cross-section. A 75 Ω video coax and a 1…
Low smoke zero halogen matters where people are evacuating and where the fire itself is the hazard — tunnels, …
Photovoltaic string cable sits outdoors for decades, at full sun, at voltages that arc if the insulation is co…
The bulk of cable in any plant is static: panel wiring, signal runs, single-core hook-up, general power. These…
MOQ 100 m · standard lead time 5-7 days · CE and RoHS documentation