A robot dress pack and a conduit inspection cable share a problem: the cable has to survive repeated tight-radius movement in a space that was not designed for it. That means high strand count, a jacket that resists abrasion against neighbouring hardware, and often a hybrid construction carrying power, signal and sometimes a camera feed in one sheath.

3.8 – 19.1 mmFinished OD
-40 to +105 °CTypical temperature
TPUMost used jacket
38Constructions
Robot and Conduit Inspection Cable
Robot and Conduit Inspection Cable
How to specify

What decides the construction

Torsion is the hidden load on a robot axis. A cable that is specified only for flexing will fail under the twist of a wrist joint, so the axis type has to be stated.

ItemTerm
Minimum order100 m
Standard lead time5-7 days ex-works
Custom constructionQuoted per duty cycle
DocumentationCE · RoHS · inspection record
Configurations in this family38

Constructions in this family

Conductor stranding, insulation, shielding, jacket, finished OD, rated temperature and minimum bend radius.

ConfigurationConductorInsulationShieldingJacketFinished ODTemperatureMin. bend radius
conduit 3×2×0.25mm²14 / 0.15PE—TPEE8.5±0.2mm40 °C~+105 °C15D(D:Cable diameter)
conduit coax 6×0.4819 / 0.18mmFEP—Matt TPUStrength member20~+125 °C15*D
conduit coax 4×0.7542 / 0.15PE—TPU10.7±1.0mm40~+ 105 °C10*D
conduit coax 4×0.7542 / 0.15PE—TPU11±1.0mm40~+ 105 °C10*D
conduit coax 4×0.7542 / 0.15PE—TPU11.4±1.0mm40~+ 105 °C10*D
robot 3×12AWG+2SMF105 / 0.2mmPE—PVC12±1.0mm30 °C~+105 °C15D(D:Cable diameter)
conduit robot 2×19AWG34 / 0.15PE—TPU6.4±0.2mm35~+ 105 °C15D(D:Cable diameter)
robot 2x6mm²+STP191 / 0.2PVC—TPU14.5±0.5mm35~+ 105 °C15D(D:Cable diameter)
robot 8×1.0mm²1.0mm²:32 / 0.2PP—PURFilling30 °C~+105 °C15D(D:Cable diameter)
conduit 7×26AWG+2D19 / 0.1PPAlumiunm foil+drain wireTPEE6.8±0.2mm40~+ 125 °C30D(D:Cable diameter)
inclinometer network UTPCAT623AWG:7 / 0.2PE—PUR—30 °C~+105 °C≤15*D
inclinometer network STPCAT623AWG:7 / 0.2PE—PUR—30 °C~+105 °C≤15*D
inclinometer 4×0.3mm²17 / 0.15PE—PU3.8±0.3mm30 °C~+105 °C15D(D:Cable diameter)
inclinometer 2×0.4mm²50 / 0.1PETinned copper shieldingTPU4.6±0.3mm30 °C~+105 °C15D(D:Cable diameter)
inclinometer 4×0.5mm²28 / 0.15TPEE—PUR4.8±0.3mm30 °C~+105 °C15D(D:Cable diameter)
downhole 2×0.75+2SMF0.75mm²: 42 / 0.15PE—PVC6.5±0.3mm30 °C~+105 °C20D(D:Cable diameter)
conduit robot tube+26×0.5mm28 / 0.15PEStength member layerTPU19.1±0.2mm35~+ 105 °C15D(D:Cable diameter)
conduit robot 4×0.75+75 3+8×0.1542 / 0.15PE—TPU11.4±1.0mm40~+ 105 °C10*D
DV conduit robot cable 12×22AWG19 / 0.15PEFillingTPU(98A)9±0.3 mm40 °C~+105 °C8-10D (D: cable diameter)
conduit robot cable 2×24AWG+2×1.37 / 0.2PP—TPEE4.0±0.1 mm40 °C~+120 °C20D (D: cable diameter)
conduit cable 2×1.0mm²+2×2×0.2mm²57 / 0.15PEFillingPUR8.7±0.3 mm30 °C~+105 °Cdynamic:8-10D (D: cable diameter)
conduit cable 2×16AWG+1×2×22AWG42 / 0.2PEFillingPUR9.3±0.3 mm30 °C~+105 °Cdynamic:8-10D (D: cable diameter)
conduit robot cable 4×0.75+75 3+4×2×0.1542 / 0.15PEAluminum foil +Tinned copper braided shieldingWaterproof bright surface TPU3.8±0.2 mm40 °C~+105 °C10D (D: cable diameter)
conduit robot cable 2×20AWG+STP CAT628 / 0.15PEFillingPolyether polyurethane10.3±0.3 mm40 °C~+90 °C10D (D: cable diameter)
robot cable 4×20AWG+8×24AWG+STP28 / 0.15PEFillingTPU13.7±0.3 mm40 °C~+105 °C20D (D: cable diameter)
robot cable 2×6+2×0.5194 / 0.2PE—TPU11.2 mm40 °C~+105 °C10D (D: cable diameter)
robot cable 2×1+2×0.556 / 0.15PE—TPU6.6 mm40 °C~+105 °C10D (D: cable diameter)
robot cable 14×24AWG+STP CAT67 / 0.2PEFillingTPU10.6±0.3 mm40 °C~+105 °C12D (D: cable diameter)
robot cable 14×24AWG+3×2×24AWG7 / 0.2PEFillingTPU(85A)11±0.3 mm40 °C~+105 °CMove: 7D (D: cable diameter)
robot cable 14×24AWG+STP CAT67 / 0.2PEFillingTPU(85A)11.6±0.3 mm40 °C~+105 °CMove: 7D (D: cable diameter)
conduit robot cable 2×22AWG+STP CAT619 / 0.15PEFillingPolyether polyurethane8.5±0.3 mm40 °C~+90 °C10D (D: cable diameter)
conduit robot cable 2×22AWG+STP CAT519 / 0.15PEFillingPolyether polyurethane8.8±0.3 mm40 °C~+90 °C10D (D: cable diameter)
conduit robot cable 2×22AWG+4×2×26AWG19 / 0.15PEAluminum foil +Tinned copper braided shieldingPolyether polyurethane7.1±0.3 mm40 °C~+90 °C8D (D: cable diameter)
conduit robot cable 2×4+STP CAT5127 / 0.2PEFillingTPU12.4±0.3 mm40 °C~+105 °C10D (D: cable diameter)
conduit robot cable 2×20AWG+STP CAT528 / 0.15TPEEBraidingTPU(matte)11±0.5 mm40 °C~+105 °C10D (D: cable diameter)
conduit robot cable 2×20AWG+4×2×0.228 / 0.15TPEEBraidingTPU(matte)9.1±0.5 mm40 °C~+90 °C10D (D: cable diameter)
conduit robot cable 2×20AWG+3×2×0.228 / 0.15TPEEBraidingTPU(matte)9.8±0.5 mm40 °C~+90 °C10D (D: cable diameter)
robot cable 4×1.2+2×0.219 / 0.28FEP—High tensile aramid fibre5.5±0.15 mm60 °C~+200 °C6-8D (D: cable diameter)

Customer identities are not published

Every construction in this table is a build we have made, described by its technical data only. The buyer, the platform it went into and the application remain that buyer's — we do not use a customer's design as a reference or a case study. If you need a reference for a comparable programme, ask at enquiry stage and we will say what we are able to share.

Common questions

Robot and Conduit Inspection Cable buying questions.

Is torsion resistance available?

Yes. Constructions in this family are laid for torsion where the axis rotates, which is a different requirement from pure flexing.

Can power and signal share one cable?

Yes. Hybrid constructions with power cores, control pairs, coax and fibre in one jacket are the majority of this family.

What is used for conduit inspection?

Small-diameter hybrid constructions carrying power, video and sometimes an air line, sized to the conduit bore.