42 constructions

Data, Coax and Network Cable

Signal cable is specified by impedance and attenuation rather than by cross-section. A 75 Ω video coax and a 120 Ω RS-485 pair are not interchangeable, and putting the wrong one on a long run costs signal margin that cannot be recovered at the receiver.

0.3 – 13.7 mmFinished OD
-30 to +105 °CTypical temperature
PVCMost used jacket
42Constructions
Data, Coax and Network Cable
Data, Coax and Network Cable
How to specify

What decides the construction

State the protocol, the run length and the impedance. Attenuation per 100 m decides whether a repeater is needed, and it is published per construction rather than assumed.

ItemTerm
Minimum order100 m
Standard lead time5-7 days ex-works
Custom constructionQuoted per duty cycle
DocumentationCE · RoHS · inspection record
Configurations in this family42

Constructions in this family

Conductor stranding, insulation, shielding, jacket, finished OD, rated temperature and minimum bend radius.

ConfigurationConductorInsulationShieldingJacketFinished ODTemperatureMin. bend radius
LSZH fixed UTP CAT67 / 0.19PE—PVC6.0±0.2mm20~+105 °C15D(D:Cable diameter)
LSZH fixed UTP CAT6A7 / 0.19PEAluminum foilPVC6.0±0.2mm20~+105 °C15D(D:Cable diameter)
coax 0.75mm²19 / 0.23mmFEPTinned wire shielding + Kevlar(Braiding)PE3.2±0.2mmFEP:-65 °C~260 °C / PE:-20 °C~80 °C15D(D:Cable diameter)
coax 0.35mm²11 / 0.2mmFEPAlloyed wire+fiber(Braiding)—2.5±0.15mm55 °C~150 °C15D(D:Cable diameter)
coax 0.35mm²11 / 0.2mmFEPTinned wire shielding(Equivalent to 0.35mm²) + Kevlar(Braiding)—2.8±0.2mm55 °C~150 °C15D(D:Cable diameter)
coax 1.0mm²16 / 0.28mmFEPTinned wire shielding(Equivalent to 1.0mm²) + Kevlar(Braiding)—3.6±0.2mm55 °C~150 °C15D(D:Cable diameter)
coax 0.15mm²19 / 0.1PE foamTinned wire shieldingTPU3.0±0.2mm30 °C~105 °C15D(D:Cable diameter)
coax RG 5828 / 0.15PETinned wire shieldingTPU4.95±0.05mm30 °C~105 °C15D(D:Cable diameter)
CAT6 (ATS 4x2x23AWG)23AWG:7 / 0.2PE—PUR—30 °C~+105 °C≤15*D
coax RG61 / 1.02PE foamAluminum foilPVC6.9±0.3mm20 °C~+75 °C25mm
fibre data 1SMF———HDPE0.35±0.05mm35 °C~+90 °C25D(D:Cable diameter)
STP CAT623AWG:7 / 0.2PE—PE7.5±0.5mm40 °C~+90 °C≤15*D
×0.75+STP CAT50.75mm²: 42 / 0.15PPFillingPUR9.2±0.3mm30 °C~+105 °C10D(D:Cable diameter)
PVC 2×RS4857 / 0.2PE—PVC6.4±0.2mm30 °C~+80 °C6~8 D (D: cable diameter)
PVC3×1.5+DMX84 / 0.15PVC—NBR9.4±0.3mm30 °C~+80 °C7-8D(D:Cable diameter)
2×22AWG+STP CAT619 / 0.15PE—TPU8.4±0.3mm30C°~ +105C°10D (D: cable diameter)
CAT5EP+2×0.5mm²+4×0.3mm²60 / 0.1PVCFillingNBR9.4±0.3 mm30 °C~+70 °C10D (D: cable diameter)
×1+2×2×1+STPCAT632 / 0.2PPFilliingWaterproof PUR13.7±0.3 mm40 °C~+105 °C15D (D: cable diameter)
CAT cable 4×2×26AWG17 / 0.1PEAluminum foil shielded separatelyPUR10.2±0.5 mm30 °C~+105 °C10D (D: cable diameter)
composite cable 3×2.5mm²+STP CAT679 / 0.2PVC—PVC11.7±0.5 mm30 °C~+70 °C15D (D: cable diameter)
CAT cable 4×2×24AWG7 / 0.2PEAluminum foil+Tinned copper wire braided overall shielding+Drain wirePUR10±0.5 mm30 °C~+105 °C10D (D: cable diameter)
PVC cable STP CAT6+3×0.75mm²42 / 0.15PVC—NBR809.7±0.3 mm20 °C~+80 °C10D (D: cable diameter)
DMX cable 2×2mm²+1×2×26AWG64 / 0.2 or 41 / 0.25PE—PUR-UV7.9±0.3 mm40 °C~+80 °C10D (D: cable diameter)
×2×0.2 TPU network25 / 0.1PE—TPU5.9±0.1 mm40 °C~+105 °C10D (D: cable diameter)
composite 3×2.5mm²+STP CAT679 / 0.2PVC—NBR12.5±0.5 mm30 °C~+70 °C15D (D: cable diameter)
composite 2×2.5mm²+STP CAT679 / 0.2PVC—PUR11.5±0.5 mm30 °C~+105 °C15D (D: cable diameter)
coax cable 2.75mm²85 / 0.2PE—PUR( 95A)7mm( )40 °C~+90 °C8D (D: cable diameter)
cable 5 12G SDI1 / 1.4PEAluminum foil+Tinned copper braided shieldingPVC8.0 mm30 °C~+70 °C15D (D: cable diameter)
cable 2 12G SDI+2×STP CAT61 / 1.4PVCAluminum foil+Tinned copper braided shieldingPVC8.0 mm30 °C~+70 °C15D (D: cable diameter)
×2+7×0.2+STP CAT6+SDI64 / 0.2PE—TPU12.2±0.5 mm40 °C~+105 °C10D (D: cable diameter)
PVC cable 4×0.5+STP CAT5+6×2×0.228 / 0.15PEFillingPVC10.9±0.3 mm20 °C~+70 °C10D (D: cable diameter)
×1+4×0.75+STP CAT6 1MPa32 / 0.2PPFilliingWaterproof PUR12±0.3 mm40 °C~+105 °C15D (D: cable diameter)
×1+4×0.75+STP CAT6 30MPa32 / 0.2PPFilliingWaterproof PUR12.6±0.3 mm40 °C~+105 °C15D (D: cable diameter)
×1+4×0.75+STP CAT6 1MPa32 / 0.2PPFilliingWaterproof PUR12.6±0.3 mm40 °C~+105 °C15D (D: cable diameter)
×1+4×0.75+STP CAT6 30MPa32 / 0.2PPFilliingWaterproof PUR13.2±0.3 mm40 °C~+105 °C15D (D: cable diameter)
×0.5+CATE628 / 0.15PPFillingTPU11.8±0.3 mm40 °C~+105 °C10D (D: cable diameter)
indoor cable 2×1.5+RS48584 / 0.15PEFillingLSZH8.8±0.3 mm40 °C~+120 °C10D (D: cable diameter)
indoor cable 2×1+RS48556 / 0.15PEFillingLSZH8.2±0.3 mm40 °C~+120 °C10D (D: cable diameter)
indoor cable 2×0.75+RS48542 / 0.15PEFillingLSZH7.8±0.3 mm40 °C~+120 °C10D (D: cable diameter)
×0.5+CAT628 / 0.15PPFillingPUR12.5±0.5 mm30 °C~+105 °C10D (D: cable diameter)
cable CAT61 / 0.57PE—LSZH6.3±0.2 mm40 °C~+105 °C8-10D(D:Cable diameter)
network 4×2×24AWG7 / 0.2PEAluminum foil+Tinned copper braided overall shielding(Over 70%)PUR6.9 mm30 °C~+105 °C10D (D: cable diameter)

Customer identities are not published

Every construction in this table is a build we have made, described by its technical data only. The buyer, the platform it went into and the application remain that buyer's — we do not use a customer's design as a reference or a case study. If you need a reference for a comparable programme, ask at enquiry stage and we will say what we are able to share.

Common questions

Data, Coax and Network Cable buying questions.

Is impedance published per construction?

Yes, where the construction is impedance-controlled. Characteristic impedance and attenuation are part of the specification for those builds.

Can coax and power share one jacket?

Yes. Composite constructions with coax, power and control pairs in one sheath are in this family.

What about network cable in a moving application?

Network constructions in this family are built with high-strand-count conductors for flexing, not solid core for static installation.

Send the duty cycle, environment and voltage. We return a construction proposal.

MOQ 100 m · standard lead time 5-7 days · CE and RoHS documentation