Signal cable is specified by impedance and attenuation rather than by cross-section. A 75 Ω video coax and a 120 Ω RS-485 pair are not interchangeable, and putting the wrong one on a long run costs signal margin that cannot be recovered at the receiver.
State the protocol, the run length and the impedance. Attenuation per 100 m decides whether a repeater is needed, and it is published per construction rather than assumed.
| Item | Term |
|---|---|
| Minimum order | 100 m |
| Standard lead time | 5-7 days ex-works |
| Custom construction | Quoted per duty cycle |
| Documentation | CE · RoHS · inspection record |
| Configurations in this family | 42 |
Conductor stranding, insulation, shielding, jacket, finished OD, rated temperature and minimum bend radius.
| Configuration | Conductor | Insulation | Shielding | Jacket | Finished OD | Temperature | Min. bend radius |
|---|---|---|---|---|---|---|---|
| LSZH fixed UTP CAT6 | 7 / 0.19 | PE | — | PVC | 6.0±0.2mm | 20~+105 °C | 15D(D:Cable diameter) |
| LSZH fixed UTP CAT6A | 7 / 0.19 | PE | Aluminum foil | PVC | 6.0±0.2mm | 20~+105 °C | 15D(D:Cable diameter) |
| coax 0.75mm² | 19 / 0.23mm | FEP | Tinned wire shielding + Kevlar(Braiding) | PE | 3.2±0.2mm | FEP:-65 °C~260 °C / PE:-20 °C~80 °C | 15D(D:Cable diameter) |
| coax 0.35mm² | 11 / 0.2mm | FEP | Alloyed wire+fiber(Braiding) | — | 2.5±0.15mm | 55 °C~150 °C | 15D(D:Cable diameter) |
| coax 0.35mm² | 11 / 0.2mm | FEP | Tinned wire shielding(Equivalent to 0.35mm²) + Kevlar(Braiding) | — | 2.8±0.2mm | 55 °C~150 °C | 15D(D:Cable diameter) |
| coax 1.0mm² | 16 / 0.28mm | FEP | Tinned wire shielding(Equivalent to 1.0mm²) + Kevlar(Braiding) | — | 3.6±0.2mm | 55 °C~150 °C | 15D(D:Cable diameter) |
| coax 0.15mm² | 19 / 0.1 | PE foam | Tinned wire shielding | TPU | 3.0±0.2mm | 30 °C~105 °C | 15D(D:Cable diameter) |
| coax RG 58 | 28 / 0.15 | PE | Tinned wire shielding | TPU | 4.95±0.05mm | 30 °C~105 °C | 15D(D:Cable diameter) |
| CAT6 (ATS 4x2x23AWG) | 23AWG:7 / 0.2 | PE | — | PUR | — | 30 °C~+105 °C | ≤15*D |
| coax RG6 | 1 / 1.02 | PE foam | Aluminum foil | PVC | 6.9±0.3mm | 20 °C~+75 °C | 25mm |
| fibre data 1SMF | — | — | — | HDPE | 0.35±0.05mm | 35 °C~+90 °C | 25D(D:Cable diameter) |
| STP CAT6 | 23AWG:7 / 0.2 | PE | — | PE | 7.5±0.5mm | 40 °C~+90 °C | ≤15*D |
| ×0.75+STP CAT5 | 0.75mm²: 42 / 0.15 | PP | Filling | PUR | 9.2±0.3mm | 30 °C~+105 °C | 10D(D:Cable diameter) |
| PVC 2×RS485 | 7 / 0.2 | PE | — | PVC | 6.4±0.2mm | 30 °C~+80 °C | 6~8 D (D: cable diameter) |
| PVC3×1.5+DMX | 84 / 0.15 | PVC | — | NBR | 9.4±0.3mm | 30 °C~+80 °C | 7-8D(D:Cable diameter) |
| 2×22AWG+STP CAT6 | 19 / 0.15 | PE | — | TPU | 8.4±0.3mm | 30C°~ +105C° | 10D (D: cable diameter) |
| CAT5EP+2×0.5mm²+4×0.3mm² | 60 / 0.1 | PVC | Filling | NBR | 9.4±0.3 mm | 30 °C~+70 °C | 10D (D: cable diameter) |
| ×1+2×2×1+STPCAT6 | 32 / 0.2 | PP | Filliing | Waterproof PUR | 13.7±0.3 mm | 40 °C~+105 °C | 15D (D: cable diameter) |
| CAT cable 4×2×26AWG | 17 / 0.1 | PE | Aluminum foil shielded separately | PUR | 10.2±0.5 mm | 30 °C~+105 °C | 10D (D: cable diameter) |
| composite cable 3×2.5mm²+STP CAT6 | 79 / 0.2 | PVC | — | PVC | 11.7±0.5 mm | 30 °C~+70 °C | 15D (D: cable diameter) |
| CAT cable 4×2×24AWG | 7 / 0.2 | PE | Aluminum foil+Tinned copper wire braided overall shielding+Drain wire | PUR | 10±0.5 mm | 30 °C~+105 °C | 10D (D: cable diameter) |
| PVC cable STP CAT6+3×0.75mm² | 42 / 0.15 | PVC | — | NBR80 | 9.7±0.3 mm | 20 °C~+80 °C | 10D (D: cable diameter) |
| DMX cable 2×2mm²+1×2×26AWG | 64 / 0.2 or 41 / 0.25 | PE | — | PUR-UV | 7.9±0.3 mm | 40 °C~+80 °C | 10D (D: cable diameter) |
| ×2×0.2 TPU network | 25 / 0.1 | PE | — | TPU | 5.9±0.1 mm | 40 °C~+105 °C | 10D (D: cable diameter) |
| composite 3×2.5mm²+STP CAT6 | 79 / 0.2 | PVC | — | NBR | 12.5±0.5 mm | 30 °C~+70 °C | 15D (D: cable diameter) |
| composite 2×2.5mm²+STP CAT6 | 79 / 0.2 | PVC | — | PUR | 11.5±0.5 mm | 30 °C~+105 °C | 15D (D: cable diameter) |
| coax cable 2.75mm² | 85 / 0.2 | PE | — | PUR( 95A) | 7mm( ) | 40 °C~+90 °C | 8D (D: cable diameter) |
| cable 5 12G SDI | 1 / 1.4 | PE | Aluminum foil+Tinned copper braided shielding | PVC | 8.0 mm | 30 °C~+70 °C | 15D (D: cable diameter) |
| cable 2 12G SDI+2×STP CAT6 | 1 / 1.4 | PVC | Aluminum foil+Tinned copper braided shielding | PVC | 8.0 mm | 30 °C~+70 °C | 15D (D: cable diameter) |
| ×2+7×0.2+STP CAT6+SDI | 64 / 0.2 | PE | — | TPU | 12.2±0.5 mm | 40 °C~+105 °C | 10D (D: cable diameter) |
| PVC cable 4×0.5+STP CAT5+6×2×0.2 | 28 / 0.15 | PE | Filling | PVC | 10.9±0.3 mm | 20 °C~+70 °C | 10D (D: cable diameter) |
| ×1+4×0.75+STP CAT6 1MPa | 32 / 0.2 | PP | Filliing | Waterproof PUR | 12±0.3 mm | 40 °C~+105 °C | 15D (D: cable diameter) |
| ×1+4×0.75+STP CAT6 30MPa | 32 / 0.2 | PP | Filliing | Waterproof PUR | 12.6±0.3 mm | 40 °C~+105 °C | 15D (D: cable diameter) |
| ×1+4×0.75+STP CAT6 1MPa | 32 / 0.2 | PP | Filliing | Waterproof PUR | 12.6±0.3 mm | 40 °C~+105 °C | 15D (D: cable diameter) |
| ×1+4×0.75+STP CAT6 30MPa | 32 / 0.2 | PP | Filliing | Waterproof PUR | 13.2±0.3 mm | 40 °C~+105 °C | 15D (D: cable diameter) |
| ×0.5+CATE6 | 28 / 0.15 | PP | Filling | TPU | 11.8±0.3 mm | 40 °C~+105 °C | 10D (D: cable diameter) |
| indoor cable 2×1.5+RS485 | 84 / 0.15 | PE | Filling | LSZH | 8.8±0.3 mm | 40 °C~+120 °C | 10D (D: cable diameter) |
| indoor cable 2×1+RS485 | 56 / 0.15 | PE | Filling | LSZH | 8.2±0.3 mm | 40 °C~+120 °C | 10D (D: cable diameter) |
| indoor cable 2×0.75+RS485 | 42 / 0.15 | PE | Filling | LSZH | 7.8±0.3 mm | 40 °C~+120 °C | 10D (D: cable diameter) |
| ×0.5+CAT6 | 28 / 0.15 | PP | Filling | PUR | 12.5±0.5 mm | 30 °C~+105 °C | 10D (D: cable diameter) |
| cable CAT6 | 1 / 0.57 | PE | — | LSZH | 6.3±0.2 mm | 40 °C~+105 °C | 8-10D(D:Cable diameter) |
| network 4×2×24AWG | 7 / 0.2 | PE | Aluminum foil+Tinned copper braided overall shielding(Over 70%) | PUR | 6.9 mm | 30 °C~+105 °C | 10D (D: cable diameter) |
Every construction in this table is a build we have made, described by its technical data only. The buyer, the platform it went into and the application remain that buyer's — we do not use a customer's design as a reference or a case study. If you need a reference for a comparable programme, ask at enquiry stage and we will say what we are able to share.
Data, Coax and Network Cable buying questions.
Yes, where the construction is impedance-controlled. Characteristic impedance and attenuation are part of the specification for those builds.
Yes. Composite constructions with coax, power and control pairs in one sheath are in this family.
Network constructions in this family are built with high-strand-count conductors for flexing, not solid core for static installation.
MOQ 100 m · standard lead time 5-7 days · CE and RoHS documentation