Manufacturer since 2015Shanghai, ChinaCE · RoHS
+86 156 1820 3882[email protected]
Request a quote
Home › Catalogue › Flat and Elevator Cable
33 constructions

Flat and Elevator Cable

A flat cable solves two geometric problems at once: it bends in one plane only, so it fits where a round cable's bend radius will not, and it resists being squashed where a round cable would roll or flatten under a moving part. The trade-off is orientation — bending a flat cable out of plane is the failure mode.

4.8 – 128.5 mmFinished OD
-20 to +80 °CTypical temperature
PVCMost used jacket
33Constructions
Flat and Elevator Cable
Flat and Elevator Cable
How to specify

What decides the construction

Flat cable must be installed with the bend plane oriented correctly, so the travel direction has to be stated. Where the run is vertical, as in elevator travelling cables, the suspended weight and the number of cores decide the tensile element.

ItemTerm
Minimum order100 m
Standard lead time5-7 days ex-works
Custom constructionQuoted per duty cycle
DocumentationCE · RoHS · inspection record
Configurations in this family33

Constructions in this family

Conductor stranding, insulation, shielding, jacket, finished OD, rated temperature and minimum bend radius.

ConfigurationConductorInsulationShieldingJacketFinished ODTemperatureMin. bend radius
flat elevator cable 24×0.7522 / 0.2mmPVC—PVC26×8.2± 0.3mm30~+70 °C≤5×D(D:Cable diameter)
flat elevator cable CAT 6e 4x2x27 / 0.2mmPVCAluminium foil+Tinned copper shielding(density≥70%)PVC10.5×7.0±0.3mm30~+70 °C≤5×D(D:Cable diameter)
flat elevator cable 8 core mult———Nitrile PVC—20 °C~+80 °C25D(D:Cable diameter)
flat 2×ATS(4×2×23AWG)7 / 0.20mmPETinned copper shielding + Aluminum foilNitrile PVC—20 °C~+80 °C15D(D:Cable diameter)
elevator flat CAT64x2x23AWG7 / 0.2(Pcs / mm)PETinned copper shielding + Aluminum foilLSZH—20 °C~+80 °C25D(D:Cable diameter)
spiral flat 4×28AWG7 / 0.1mmPP—PVC2.4×4.8±0.2mm30 °C~+70 °C15D(D:Cable diameter)
flat 4×STP CAT67 / 0.2mmPEAluminum foil+Tinned copper shieldingPVC6.0mm±0.2mm30~+70 °C5D(D:Cable diameter)
flat 7×50mm²1018 / 0.25PVC—Nitrile rubber17.2±1.5mm×128.5±3.0mm20~+80 °C5D(D:Cable diameter)
flat UTP CAT6A+1SMF7 / 0.19PEAluminum foilPVC11.2±1.0mm×7.0±0.5mm20~+105 °C25D(D:Cable diameter)
flat 8×0.75+4×OM342 / 0.15PVC—PVC43±2.5mm×5.2±0.3mm20~+80 °C25D(D:Cable diameter)
flat 4×1.585 / 0.15PVC—PVC19±1.5mm×5.0±0.3mm20~+80 °C25D(D:Cable diameter)
flat 9×2.5mm²9 2.5mm²:77 / 0.2PVCWrappingLSZH( , )72±1.5mm × 10±0.3mm25 °C~+70 °C70mm
flat 2x23AWG+1SMF7 / 0.2PE—Nitrile—20 °C~+80 °C25D(D:Cable diameter)
elevator flat 4SMF———PVC5.0±0.3mm20 °C~+80 °C25D(D:Cable diameter)
flat 2×6.0+STP CAT66.0mm²:191 / 0.2PVCBraidingPVC19.4±1.5mm ×7.4±0.5mm20 °C~+80 °C25D(D:Cable diameter)
flat 4×3.0+4×2×23AWG3.0mm²:95 / 0.2PVCBraidingPVC27.4±1.5mm ×5.4±0.5mm20 °C~+80 °C20D(D:Cable diameter)
flat 3×13.3+3×20AW13.3mm²:270 / 0.25PVC—NBR30.8±1.5mm × 9.5±0.5mm20 °C~+80 °C20D(D:Cable diameter)
flat 13×2.5 DMX79 / 0.2PVC—LSZH65±3mm × 9±3mm30 °C~90 °C15D(D:Cable diameter)
flat 255×0.75mm²42 / 0.1580—LSZH100±10 mm × 34±2 mm30 °C~+90 °C15D (D: cable diameter)
elevator flat 2MMF———PVC5.0±0.3 mm20 °C~+80 °C25D(D:Cable diameter)
elevator cable 10×2×20AWG TS+8MMF28 / 0.15PVC—PVC4.8 mm10 °C~+60 °C20-25D (D: cable diameter)
elevator flat 4SMF———PVC5.0±0.3 mm20 °C~+80 °C25D (D: cable diameter)
elevator flat STP CAT6 428 / 0.1PEAluminium foil+ Tinned copper braided shieldingNBR—20 °C~+80 °C10D (D: cable diameter)
elevator flat STP CAT6 828 / 0.1PEAluminium foil+ Tinned copper braided shieldingNBR—20 °C~+80 °C10D (D: cable diameter)
elevator cable 4MMF———PVC5.0±0.3mm20 °C~+80 °C25D(D:Cable diameter)
elevator cable UTP CAT5E7 / 0.2PE—PUR6.7±0.3 mm30 °C~+105 °C8-10D(D:Cable diameter)
elevator flat 12SMF———LSZH—20 °C~+80 °C25D (D: cable diameter)
flat 4×STP CAT67 / 0.2 mmPEAluminum foil+Tinned copper shieldingPVC6.0±0.2 mm20 °C~+70 °C7D (D: cable diameter)
elevator flat 4×2.5+2×STP CAT62.5mm²: 79 / 0.2 mmPE—PVCStrength member20 °C~+70 °C10D (D: cable diameter)
elevator flat 40×0.75mm²42 / 0.15PVC—PVC58.9±2 mm × 7.8±0.5 mm20 °C~+70 °C15D (D: cable diameter)
LSZH flat 9×1.5+4×2.548 / 0.2PVC—LSZH74.6±3mm × 9±3mm40 °C~+120 °C15D (D: cable diameter)
LSZH flat 9×1.5+4×2.548 / 0.2PVC—LSZH76.2±3mm × 9±3mm40 °C~+120 °C15D (D: cable diameter)
flat 3×35+1×1635mm²: 264 / 0.4 mmEPDM rubber—NBR80±3.0 mm×25±1.0 mm30 °C~+90 °C8D (D: cable diameter)

Customer identities are not published

Every construction in this table is a build we have made, described by its technical data only. The buyer, the platform it went into and the application remain that buyer's — we do not use a customer's design as a reference or a case study. If you need a reference for a comparable programme, ask at enquiry stage and we will say what we are able to share.

Common questions

Flat and Elevator Cable buying questions.

Why use flat cable instead of round?

It bends in a single plane, fitting a tighter envelope than a round cable of the same cross-section, and it resists compression. The constraint is correct orientation at installation.

Is it suitable for elevator travelling cables?

Yes. Several constructions in this family are built for vertical travel with suspended weight, carrying power and signal in one flat profile.

Can fibre be included?

Yes. Flat constructions with single-mode or multi-mode fibre alongside copper are in this family.

Send the duty cycle, environment and voltage. We return a construction proposal.

MOQ 100 m · standard lead time 5-7 days · CE and RoHS documentation