Manufacturer since 2015Shanghai, ChinaCE · RoHS
+86 156 1820 3882[email protected]
Request a quote
Home › Catalogue › LSZH Cable
10 constructions

LSZH Cable

Low smoke zero halogen matters where people are evacuating and where the fire itself is the hazard — tunnels, rolling stock, enclosed public spaces. The compounds involved are harder to process than PVC and cost more, so they are specified where the standard demands them rather than as a default.

4.5 – 18.0 mmFinished OD
-40 to +120 °CTypical temperature
LSZHMost used jacket
10Constructions
LSZH Cable
LSZH Cable
How to specify

What decides the construction

State the fire standard the installation is accepted against. Halogen content, smoke density and flame propagation are tested separately, and the certificate has to match the standard the project names.

ItemTerm
Minimum order100 m
Standard lead time5-7 days ex-works
Custom constructionQuoted per duty cycle
DocumentationCE · RoHS · inspection record
Configurations in this family10

Constructions in this family

Conductor stranding, insulation, shielding, jacket, finished OD, rated temperature and minimum bend radius.

ConfigurationConductorInsulationShieldingJacketFinished ODTemperatureMin. bend radius
other LSZH37x22AWG22AWG: 11 / 0.2PE—LSZH14.2±0.3mm25 °C~+80 °C15D(D:Cable diameter)
LSZH 4×2×0.634 / 0.15PETinned copper braiding(density80%)Matt LSZH9.8±0.3mm25~+90 °C10D(D:Cable diameter)
LSZH fixed ATS 6×1.51.5mm²:85 / 0.15PEAluminum foil+Tinned copper braidingLSZH14.4±0.5mm20~+90 °C15D(D:Cable diameter)
LSZH 4×10AWG14AWG :64 / 0.2LSZH—LSZH4.5mm20 °C~+105 °C20D(D:Cable diameter)
LSZH 50mm²1018 / 0.25XLPETinnd copper shieldingFlame retardant TPU(80%)18±1.0mm35 °C~80 °C6~8D(D:Cable diameter)
LSZH 2×14AWG14AWG :64 / 0.2PE—LSZH8.2±0.3mm20 °C~+105 °C15D(D:Cable diameter)
LSZH cable 2×0.75+6×0.342 / 0.15PVC—LSZH7±0.3 mm40 °C~+120 °C10D (D: cable diameter)
LSZH cable 2×0.75+3×0.342 / 0.15PVC—LSZH6.5±0.3 mm40 °C~+120 °C10D (D: cable diameter)
LSZH cable 2×2×0.3mm²19 / 0.15FEP—LSZH6.8±0.3 mm40 °C~+120 °C8-10D (D: cable diameter)
LSZH cable 2×1.5+1×2×0.5P48 / 0.2PEFillingLSZH9±0.3 mm40 °C~+105 °C10D (D: cable diameter)

Customer identities are not published

Every construction in this table is a build we have made, described by its technical data only. The buyer, the platform it went into and the application remain that buyer's — we do not use a customer's design as a reference or a case study. If you need a reference for a comparable programme, ask at enquiry stage and we will say what we are able to share.

Common questions

LSZH Cable buying questions.

What does LSZH actually limit?

Halogen content in the combustion products, and smoke density. Both are tested separately, and the applicable standard is set by the installation rather than by the cable.

Is LSZH suitable for outdoor use?

It depends on the compound — some LSZH grades are UV stabilised and some are not. State the exposure and the jacket is selected accordingly.

Does LSZH cost more?

Yes. The compounds are more expensive and harder to process than PVC, which is why they are specified against a requirement rather than as standard.

Send the duty cycle, environment and voltage. We return a construction proposal.

MOQ 100 m · standard lead time 5-7 days · CE and RoHS documentation