Low smoke zero halogen matters where people are evacuating and where the fire itself is the hazard — tunnels, rolling stock, enclosed public spaces. The compounds involved are harder to process than PVC and cost more, so they are specified where the standard demands them rather than as a default.
State the fire standard the installation is accepted against. Halogen content, smoke density and flame propagation are tested separately, and the certificate has to match the standard the project names.
| Item | Term |
|---|---|
| Minimum order | 100 m |
| Standard lead time | 5-7 days ex-works |
| Custom construction | Quoted per duty cycle |
| Documentation | CE · RoHS · inspection record |
| Configurations in this family | 10 |
Conductor stranding, insulation, shielding, jacket, finished OD, rated temperature and minimum bend radius.
| Configuration | Conductor | Insulation | Shielding | Jacket | Finished OD | Temperature | Min. bend radius |
|---|---|---|---|---|---|---|---|
| other LSZH37x22AWG | 22AWG: 11 / 0.2 | PE | — | LSZH | 14.2±0.3mm | 25 °C~+80 °C | 15D(D:Cable diameter) |
| LSZH 4×2×0.6 | 34 / 0.15 | PE | Tinned copper braiding(density80%) | Matt LSZH | 9.8±0.3mm | 25~+90 °C | 10D(D:Cable diameter) |
| LSZH fixed ATS 6×1.5 | 1.5mm²:85 / 0.15 | PE | Aluminum foil+Tinned copper braiding | LSZH | 14.4±0.5mm | 20~+90 °C | 15D(D:Cable diameter) |
| LSZH 4×10AWG | 14AWG :64 / 0.2 | LSZH | — | LSZH | 4.5mm | 20 °C~+105 °C | 20D(D:Cable diameter) |
| LSZH 50mm² | 1018 / 0.25 | XLPE | Tinnd copper shielding | Flame retardant TPU(80%) | 18±1.0mm | 35 °C~80 °C | 6~8D(D:Cable diameter) |
| LSZH 2×14AWG | 14AWG :64 / 0.2 | PE | — | LSZH | 8.2±0.3mm | 20 °C~+105 °C | 15D(D:Cable diameter) |
| LSZH cable 2×0.75+6×0.3 | 42 / 0.15 | PVC | — | LSZH | 7±0.3 mm | 40 °C~+120 °C | 10D (D: cable diameter) |
| LSZH cable 2×0.75+3×0.3 | 42 / 0.15 | PVC | — | LSZH | 6.5±0.3 mm | 40 °C~+120 °C | 10D (D: cable diameter) |
| LSZH cable 2×2×0.3mm² | 19 / 0.15 | FEP | — | LSZH | 6.8±0.3 mm | 40 °C~+120 °C | 8-10D (D: cable diameter) |
| LSZH cable 2×1.5+1×2×0.5P | 48 / 0.2 | PE | Filling | LSZH | 9±0.3 mm | 40 °C~+105 °C | 10D (D: cable diameter) |
Every construction in this table is a build we have made, described by its technical data only. The buyer, the platform it went into and the application remain that buyer's — we do not use a customer's design as a reference or a case study. If you need a reference for a comparable programme, ask at enquiry stage and we will say what we are able to share.
LSZH Cable buying questions.
Halogen content in the combustion products, and smoke density. Both are tested separately, and the applicable standard is set by the installation rather than by the cable.
It depends on the compound — some LSZH grades are UV stabilised and some are not. State the exposure and the jacket is selected accordingly.
Yes. The compounds are more expensive and harder to process than PVC, which is why they are specified against a requirement rather than as standard.
MOQ 100 m · standard lead time 5-7 days · CE and RoHS documentation