Manufacturer since 2015Shanghai, ChinaCE · RoHS
+86 156 1820 3882[email protected]
Request a quote
Home › Products › UAV tether cable
Persistent UAV power

UAV Tether Cable, 50 kN Tensile

Hybrid power and optical construction for a UAV that stays up: 50 kN tensile strength, 750 V to 3 kV working voltage and one G.657A2 fibre in the same jacket.

50 kNTensile
3 kVMax voltage
G.657A2Fibre
100 mMOQ
UAV tether cable with power conductors and optical fibre
UAV tether cable, 50 kN tensile
Construction

UAV tether cable — specification

A tether carries three things at once: power up, data down, and the mechanical load of the aircraft. Putting them in one jacket saves the weight of separate cables, which is the whole point — every gram of tether is a gram the aircraft has to lift. The 50 kN tensile rating comes from the strength member rather than the conductors, so the copper is never load-bearing. G.657A2 fibre is specified because it tolerates the tight bend at the winch and at the airframe connection without the bend loss that standard single-mode fibre shows.

To quote this construction we need
  • Working voltage at the winch
  • Continuous and peak current draw
  • Tensile load and safety factor
  • Fibre count and connector at each end
Send these details
ParameterValue
Tensile strength50 kN
Optical fibre1 core, G.657A2
Conductortinned copper
Insulation and jacketTPEE
Operating temperature-40 to +80 °C
Rated voltage750 V to 3 kV
Standard basiscustomer specification
Minimum order100 m
Construction range in this family
Configurations in this family160 builds
ShieldingTinned wire shielding(Equivalent to 0.35mm²) + Kevlar(Braiding)
Jacket / outer sheathHigh tensile aviation fiber
Finished OD0.3 – 13.6 mm
Rated temperature-60 °C to ﹢200 °C
Reference standardAccording to customer's requirements.
Most common bend radius20D
Full construction table160 builds with stranding, OD, shielding and bend radius →

Where it is used

Tethered flight, where endurance matters more than freedom.

Tethered UAV platforms
Persistent surveillance
Telecom relay
Broadcast and events
Emergency response
Border and perimeter monitoring

Common questions

UAV tether cable buying questions.

What is the tensile strength of the tether?

50 kN, carried by the strength member rather than the conductors. The copper is never load-bearing, so a tensile event does not stretch or break the power path.

What fibre is used?

One core of G.657A2 bend-insensitive single-mode fibre, specified for the tight bend radius at the winch and at the airframe connection.

How much power can it carry?

Power capacity depends on conductor cross-section and the voltage at the winch. The construction is built for working voltages from 750 V up to 3 kV, so it is specified per platform rather than quoted as a single figure. Send the aircraft's continuous and peak draw and the winch output voltage.

Can the fibre count be increased?

Yes. Additional fibre cores and additional copper pairs are specified per order, from 100 m.

Send the duty cycle, environment and voltage. We return a construction proposal.

MOQ 100 m · standard lead time 5-7 days · CE and RoHS documentation